New building codes and requirements have recently been updated in several coastal states to provide increased protection for lives and properties against hurricanes.  The Florida building code pioneered this trend in March 2002.  Several states are now adopting the FBC standards.

In those areas, fenestration products are now asked to withstand winds up to 150 miles per hour.  This new requirement suggests the use of approved hurricane shutters or certified windows and doors.  The Impact Jazz Sliding Door is becoming the standard in hurricane protection.  It offers Maximum Protection against hurricanes and associated wind-borne debris.  

The impact-approved Impact Jazz Sliding Door uses Cardinal Glass Sea Storm laminated glass.  It provides unequalled protection.  Sea Storm looks like ordinary glass.  It is reinforced with a layer of 0.090” of PVB in between two sheets of glass.
Secondary Lock for Impact Resistance
Frame :
• All PVC multi-chamber profiles 5-5/8”
• Extruded-on nailing fin, full 4-9/16” behind fin
• Welded or mechanically fastened frame
• Anodized aluminum threshold
• Continuous Dual Weatherstripping

Options :
• Interior brass handle
• Key lock
• Foot lock
• Security bar
• Corrosion-resistant hardware package
• Extension jambs
• Brick mould with aluminum sill extension

Performance :
The Impact Jazz Sliding Door has successfully met the following standards :
• Canada: CAN /CGSB-82.1-M89
• USA: AAMA / NWWDA 101/I.S 2-97
• CSA certified
• Product #FL 6778
• Airtighness:  Canadian: A-3, USA: DP-50 Rated
• Water resistance:   Canadian: B-4
• Structural Resistance: Canadian: C-3, , USA: Standard configuration up to 6/0 x 6/8, Optional configuration up to 8/0 x 8/0
FusionDoor2.jpg
“D” Shape
Handle
with
Lever
285, Grand-Bernier North, Saint-Jean-sur-Richelieu, Quebec, Canada, J3B 4R3
South Shore: (450)347-3737       Montreal: (514) 861-1765          Fax:  (450) 347-8890
FusionDoor.jpg
Our products
Impact Jazz Sliding Door
Lock.jpg
Lock.jpg
JazzSlidingHandle.jpg
Impact Testing
(State of Florida)

• TAS 201 (impact large missile level D)
• TAS 202 (design load, air infiltration, water penetration, uniform load FER)
• TAS 203 (cycle testing)